IECEx-certified repair, overhaul and reclamation of explosion-protected motors and generators (Ex d, Ex e, Ex n/ec, Ex p, Ex t) to IEC 60079-19:2019 under certificate IECEx UL S0019, so the machine keeps its certification.
The same controlled route for a 10 kW pump motor and a 13.8 kV compressor drive; Ex machines add the IEC 60079-19 checks at every step.
Step 1
Incoming inspection & assessment
Nameplate and Ex-marking verification, electrical tests, core-loss, dimensional and vibration baseline. You receive a documented report and a fixed-scope quotation.
Step 2
Approval & engineering
Winding data confirmed against OEM records or reverse-engineered; repair method, insulation system and critical dimensions defined before work starts.
Step 3
Repair, rewind & machining
Stripping in the burn-off oven, rewinding in the temperature-controlled area, VPI impregnation, machining and reclamation, balancing to 5 tons.
Step 4
Test, certify & return
Solo run to 4,000 kW, high-voltage tests to 13.8 kV, vibration and balancing results on the test certificate; Ex repair marking and report where applicable; delivery or on-site commissioning.
Capacity that matches the Kingdom's heaviest plants
Published capabilities of the Dammam facility.
Lifting capacity
20tons
Overhead cranes for motors and equipment up to 20 tons
High-voltage AC testing
13.8kV AC
Test facilities designed for high-voltage AC equipment up to 13.8 kV
DC testing & operation
1,000V DC
DC equipment testing and operation up to 1,000 V
Solo-run testing
4,000kW
Equipped to perform solo-run tests up to 4,000 kW
Motors repaired to date
50,000+
Across Saudi Arabia and the GCC since 1988
Saudi Arabia and the GCC (UAE, Kuwait, Bahrain, Qatar, Oman)
Need this service?
Tell us about the machine and the fault. We respond with a scope and a quotation.